Scenario
An off-grid pumping system with a 380 V three-phase pump, using a PV550 G3 (380–480 V) inverter. How many panels per string? The common shortcut — rated panel voltage times panel count — is where failures start.
Principle: two voltages, not one
Chapter 3 of the manual gives DC 250V-800Voc for the 380–480 V models, together with the MPPT voltage window (source S-01 Ch. 3):
| Quantity | G3 (380–480 V) |
|---|---|
| Solar DC input (Voc) | 250–800 V DC |
| MPPT voltage range (Vmp) | 250–800 V DC |
| Recommended MPPT (Vmp) | 350–800 V DC |
Voc is the open-circuit ceiling; Vmp is the operating window. They are not interchangeable — HBDTECH's PV550 inquiry knowledge base lists this as a known discrepancy to watch (source S-07). Voc sets the maximum string length; Vmp sets the minimum. Too few panels and the operating point drops out of the MPPT window; too many and cold-weather Voc breaks 800 V.
Method: three steps
- Compute cold-temperature Voc:
Voc(cold) = Voc(STC) × [1 + temperature coefficient × (minimum ambient − 25 °C)], with Voc(STC) and the coefficient taken from the module datasheet (the coefficient is negative for crystalline silicon, so Voc rises as temperature falls). - Cap the ceiling: panels per string × Voc(cold) must stay below 800 V DC, with engineering margin — do not design against the limit.
- Check the floor: panels per string × Vmp(at operating temperature) must land inside the MPPT window; for a 380 V pump, array Voc should reach at least 620 V, with array power at least 1.2× the pump rating (source S-08).
This went wrong in a real design
A river-irrigation design with 96 panels in 16 strings × 6 parallel was flagged during document review: 16 panels in series may exceed the 800 V DC limit of the G3 models at low temperature (source S-04, case 3, open item 1). The item is still open and the design is not presented as validated (see case 3).
Cautions
- Do not estimate with panel count × nominal voltage: nominal voltage is an operating value, not a cold open-circuit voltage.
- High altitude and high albedo (water, snow) lower module temperature and raise irradiance; leave margin at both ends.
- Module degradation does not buy you low-temperature margin — the two are not the same order of magnitude.
- Ratings are model-specific; this article gives the method, and each project must be recomputed from the module datasheet.